Transformers of this type are used in the steel melting and metallurgical industry. They are characterised by high secondary current(for steel up to 90 kA and for ferroalloy upto 160 kA electrode current) and a wide secondary voltage range. The secondary voltage is normally regulated by an on - load tap changer (OLTC) located in the high voltage winding or in an intermediate circuit of a two-cored design within the transformer tank.
Rating | : | Upto 12MVA |
Primary Voltage | : | 33kV |
Secondary Voltage | : | As per requirement |
No. Of Phase | : | One / Three |
Cooling | : | ONAN / ONAF / AFWF |
Applicable Standard | : | IS, IEC, IEEE, ANSI, JIS etc |
Winding Material | : | Copper |
Insulation Class | : | A |
Constructional Features | : | Conventional Tank Mounted, Cover / Lead Mounted Type |
"Off Circuit Manually Operated" and "On Load Tap Changer"(OLTC) with AVR and RTCC panel
Rating | : | Upto 5,000kVA |
Primary Voltage | : | Upto 33kV |
Frequency | : | 50 / 60 Hz or as per requirement |
Vector Group | : | Scott-T |
Cooling | : | ONAN |
Applicable Standard | : | IS, IEC, IEEE, ANSI, JIS etc |
Winding Material | : | Copper / Aluminium |
Insulation Class | : | A |
Constructional Features | : | Conventional Tank Mounted, Cover Mounted Type, Hermetically Sealed Tank |
Raychem RPG's Oil Immersed Power Transformers are manufactured in accordance with the most demanding industry and international standards. Transformers can be provided with off-load and on-load tap changers.
Rating | : | Upto 25MVA |
Primary Voltage | : | Upto 132kV |
Secondary Voltage | : | As per requirement |
No. of Phase | : | Three |
Cooling | : | ONAN / ONAF / AFWF |
Applicable Standard | : | IS, IEC, IEEE, ANSI, JIS etc |
Winding Material | : | Copper |
Insulation Class | : | A |
Constructional Features | : | Conventional Tank Mounted, Cover Mounted Type |
In hermetically sealed transformer, pressure variation due to oil expansion & contraction is absorbed by the flexible corrugated steel tank(variable volume tank design), where by the maximum operating pressure remains at only a fraction of the usual. Transformers are always shipped completely filled with oil and sealed for their lifetime. Bushings can be exchanged from the outside draining the oil below the top of the active part.
The cover is equipped with a filling pipe which is high enough to ensure a safe oil filling level in the insulating elements at all times for the bushing.
Hermetically sealed Transformers are used in high humid environment, where there is limitation of maintenance services and there is a confined space condition such as package or compact substation units.
Dry type Cast Resin Transformers are designed & tested to comply with National & International Standards IS / BIS / ANSI / IEC & IEEE.
Casting based on semi-filled system(with automatic filer loading)
Rating | : | Upto 10 MVA |
Voltage Class | : | Upto 33kV |
Frequency | : | 50 / 60 Hz or as per requirement |
Vector Group | : | Dyn11 / YNd11 / Dyn1 |
Cooling | : | ANAN / ANAF |
Applicable Standard | : | IS, IEC, IEEE, ANSI, JIS etc |
Winding Material | : | Copper / Aluminium |
Insulation Class | : | F / H / C |