Arrangement type | : | Horizontal Type |
Breaker Number | : | 1 |
Rated Voltage | : | 252kV |
Rated Current | : | 4000A |
Rated Frequency | : | 50Hz / 60Hz |
First-pole-to-clear Factor | : | 1.3 |
Rated short-circuit breaking current | : | 50kA |
Rated short-time withstand current(RMS) | : | 50kA |
Rated duration of short-time | : | 3s |
Rated peak withstand current(Peak value) | : | 50Hz : 125kA / 60Hz : 130kA |
Rated short-circuit making current(peak value) | : | 50Hz : 125kA / 60Hz : 130kA |
Rated lighning impluse withstand voltage(peak value) Phase-to-earth and between phases / Across breaker |
: | 1050kV / 1050kV+206kV |
Rated 1min power frequency withstand voltage(RMS) Phase-to-earth and between phases / Across breaker |
: | 460kV / 460kV+145kV |
Short-line breaking current | : | 45kV / 37.5kA |
Rated out of phase breaking current | : | 12.5kA |
Rated out of phase breaking current | : | 200A |
Rated out of phase breaking current | : | 12.5kA |
Rated cable - charing breaking current | : | 250A |
Breaking time | : | 50ms |
Rated operating sequence | : | O-0.3s-CO-180s-Co |
Operation Meathod | : | level operation |
Mechanical life | : | 10000 times |
Breaking times of rated short-circuit current | : | 20 times |
SF6 gas pressure (20'C) Rated pressure / Alaram pressure / Blocking pressure of circuit breaker |
: | 0.72 MPa / 0.68 MPa / 0.65 MPa |
Rated voltage | : | 252kv |
Rated current | : | 4000A |
Rated frequency | : | 50Hz / 60Hz |
Rated short-time with stand current (RMS) | : | 50kA |
Rated duration of short-time | : | 3s |
Rated peak withstand current( peak value) | : | 50Hz: 125kA 60Hz: 130kA |
Rated voltage | : | 252kv |
SF6 gas pressure (20'C) Rated pressure / Alaram pressure |
: | 0.68MPa / 0.63MPa |
Rated lightning impulse withstand voltage (peak value) Phase-to-earth and between phases / Across the isolating distance |
: | 1050kV / 1050kV+206kV |
Rated power frequency 1 min withstand voltage (RMS) Phase-to-earth and between phases / Across the isolating distance |
: | 460kV / 460kV+145kV |
Opening and closing time | : | <=2s |
Mechanical life | : | 10000times / 10000times |
Rated capacitive current | : | 2A |
Rated inductive current | : | 2A |
Switching bus-transfer current Transfer current / Transfer voltage / Transfer times |
: | 1600A / 100A / 100times |
Rated voltage | : | 252kv |
Rated frequency | : | 50Hz / 60Hz |
Rated short-time withstand current (RMS) | : | 50kA |
Rated duration of short-time | : | 3s |
Rated peak withstand current (peak value) | : | 50Hz: 125kA 60Hz: 130kA |
Rated short-circuit making current | : | 50Hz: 125kA 60Hz: 130kA |
Minimum operation voltage | : | 85% Ur |
Making times of rated short-circuit current | : | => 2 times |
Opening and closing time | : | 105s~3.0s |
Mechanical life | : | 10000 times |
Rated inductive current | : | 160A |
Rated capacitive current | : | 10A |